From failed inspections to leaking penetrations, these are the issues building owners bring to us most often.
NEC 440-14 requires a disconnect that is visible and accessible from the equipment it controls, and a distant or obstructed disconnect fails this requirement regardless of measured distance. This is a common finding during rooftop inspections. We relocate or add a disconnect that genuinely meets the sightline requirement.
Field-installed wiring without a proper wet-location raceway is one of the most common reasons a rooftop inspection gets red-tagged. Rain enters through the same louvers that ventilate the unit. We install wiring in code-compliant raceway rated for that exposure.
A maintenance receptacle connected to the load side of the disconnect leaves technicians without power for their tools exactly when the unit is shut off for service. This defeats the entire purpose of the outlet. We confirm and correct line-side wiring on every rooftop connection.
A penetration sealed without coordinating with roofing standards can fail and cause interior water damage that shows up far from the actual hole. This can also void a roof's warranty. We coordinate sealing methods with roofing contractors before any penetration is made.
Conduit not properly supported at regular intervals can loosen from wind exposure and constant equipment vibration over time. A run that looked solid at installation can fail within a year or two. We support conduit runs to the standard rooftop exposure actually demands.
OSHA 1910-147 requires a disconnect capable of being locked in the open position so technicians can work safely inside the unit housing. A disconnect without this capability adds real danger to routine maintenance. We install lockable disconnects on every rooftop project.
A rooftop with several units sharing a disconnect board becomes a hazard when labeling is unclear, risking the wrong switch being thrown during an emergency. This is a common gap on older multi-unit rooftops. We install clear, durable labeling on every grouped disconnect installation.
A failed inspection almost always traces back to one of a few specific issues: sealing, support, receptacle wiring, or disconnect placement. Correcting these after equipment is running costs far more than doing it right the first time. We diagnose exactly what failed and correct it efficiently.
Reconnecting an existing unit sometimes means working around a disconnect or conduit routing that was never done to standard. Simply matching the old setup passes the problem along. We flag inherited issues honestly and recommend the right fix.
Thorold Electrical Services found our previous contractor had run open wiring inside the unit housing with no raceway. They corrected it before our scheduled inspection and we passed without a single note.
We were nervous about a new penetration voiding our roof warranty but they worked directly with our roofing contractor to confirm the sealing method first. No issues since installation.
A storm delayed the crew by two days but Thorold Electrical Services communicated ahead of time and the actual installation was clean and fast once weather cleared. Would use them again.
Our maintenance outlet up on the roof had never actually worked because it was wired on the wrong side of the disconnect. They caught it during an unrelated service call and fixed it properly.
We had four rooftop units needing new disconnects and they handled the whole job in a single coordinated day instead of four separate trips. Saved us real money on labor.
Thorold Electrical Services could have just reconnected our unit to match what was already there but instead flagged that our disconnect was never properly labeled. Appreciated the honesty even though it added a bit to the job.

Describe the property and the problem. If it is a second opinion on somebody else's quote, send that over too — those are free and often worth a lot.
Demand recorded and circuits traced before anything is recommended. It is the step most contractors skip and the one that changes the answer most often.
Specified for service life rather than for the quote, with every device named so a cheaper price can be compared on what it leaves out.
Tested under load, inspected, documented, and warrantied for two years on our labour.
Tell Thorold Electrical Services about a recurring fault, a tripping breaker or a dead circuit anywhere in Thorold.
A fault that survives two visits is usually a termination rather than the part everybody keeps replacing.